Specifications
Capacity, t.
up to 3.2
Boom outreach, m.
up to 5.0
Lifting height, m.
up to 36.0
Angle of rotation
up to 180 dg.
Drive type
manual / electric
Design number of full load cycles according to ISO 4301/1
A2 and above
Environmental class according to GOST 15150-69
U1 (outdoors) / U2 (under a canopy) / U3 (indoors) / U4 (under the canopy)
The design of the crane
General-purpose industrial version / Fire-safe version / Explosion-proof version
List of additional options
By default, cranes are manufactured as standard. But depending on their technical characteristics and operating conditions, the plant manager may recommend supplementing the standard equipment with one or another set of options. Below is a brief description of them and the validity of the installation.

Name of the optionDescription of the option
Load capacity limiterIt is used as an additional safety device along with limit switches and a load drop protection device in case of phase breakage. It is installed, as a rule, in cases where work is carried out with different loads, the mass of which is not always known. If the weight of the load exceeds the lifting capacity of the hoist, the limiter blocks the lifting process. The option is available for cranes equipped with an electric hoist, since the limiter is mounted on the lifting mechanism of the hoist.
Sound and light alarmsThe alarm is activated when the jib crane is turned on, warning employees to leave the danger zone. Depending on the conditions of the working area, it is recommended to install a light or sound alarm. The option is available only for electric jib cranes.
Radio controlAllows you to control the crane from a distance using the remote control. The option is available for electric jib cranes or for cranes equipped with an electric hoist. The package includes a 6-button remote control with an emergency stop button, a radio signal receiver (installed on the hoist or on the crane control box or next to the control box).
Electric motor with boom turn brakeThe built-in brake allows you to stop the crane boom in the right place of non-stop movement of the equipment by inertia. It is impossible to manually fix the console at a strictly necessary point. Visually, the brake on the crane structure is not visible, since it is an element of the gearbox motor design. The option is recommended to be installed for cranes with the placement category U1 and U2 to prevent spontaneous movement of the boom in the parking position with wind gusts and other external factors.
Carport for parking hoists when performing "On the street"They are used on cranes of the placement category U1 (on the street) to protect the electric hoist from direct precipitation. It is recommended for installation by manufacturers of cranes and hoists, since the hoists themselves usually do not provide alternative protection from precipitation.
A canopy for a hoist for the entire length of the span when performed "On the street"They are used on cranes of the placement category U1 (on the street) to protect the electric hoist from direct precipitation. It is recommended for installation by manufacturers of cranes and hoists, since the hoists themselves usually do not provide alternative protection from precipitation.
Power off on the crane columnAllows you to turn on/off the tap power. It is located at a height of about 1500 mm from the lower flange of the crane. It is a two-button post in a protective (metal) casing.
Electric limit switches for the movement of hoists along the crane boomThey are used to limit the path of the electric hoist along the crane console.
Anchor system for fixing the crane to the foundationThis option refers to the stage of installation of the structure. Anchors are needed to attach the crane to the foundation. As a rule, we offer an anchor system for implementation on a prepared foundation. On an unprepared foundation, so-called mounting studs are used.
Load drop protection device in case of phase breakageAn additional safety device along with a load capacity limiter and limit switches.
Logger of crane operation parametersRegisters the operating conditions of the crane, including modes, duration and volume of loading. It is installed only when the crane is equipped with an electric rope hoist.
Crane operating time indicatorControls the operating time of the crane, allowing time to carry out the necessary maintenance, maintenance and overhaul. It is built either into the door of the crane control box, or inside it.
Frequency control of the boom rotation speedThe frequency converter is installed in the crane control box for the possibility of adjusting the boom rotation speed in a certain range. It can also perform smooth start and braking.
Engine cooling systemIt is recommended to use when installing a frequency converter, which will significantly limit the standard speed of movement of the crane, to prevent overheating of electric motors.
Input throttleSmoothes the front and reduces the amplitude of the emission of bursts of alternating power supply voltage. Reduces the amplitude of the ripple current consumed by the frequency converter from the mains.
Platform and ladder for maintenance of hoists and crane componentsWhen ordering a jib crane with a height of more than 3 meters, it is recommended to immediately provide ways of servicing the hoist, oil change and other maintenance operations. One of the options is to install a horizontal platform on the column at a human-height distance from the console and a ladder welded to the crane column leading to this platform.
Heated crane control boxAllows you to operate a jib crane at air temperatures up to -20 g. C (inclusive). It is required to be installed on all cranes that are operated at an air temperature below -10 g. s. Requires additional installation of a frequency converter.
Description

Our company designs and manufactures special jib cranes used to solve a wider range of tasks or in non-standard conditions. The pillar double jib crane is designed for mechanization of work on lifting and moving loads. Thanks to the presence of two consoles, the crane serves two working areas, saving space at the expense of a single column. Each console can be used independently. The angle of rotation of the console is limited to an angle of 180°.

The "Gruzopodyem" plant produces a pillar double jib crane in accordance with the Technical Regulation of the Customs Union 010/2011 "On the safety of machinery and equipment" with a lifting capacity of up to 3.2 tons and a boom reach of up to 5.0 meters with a manual or electric drive for turning the console.

Pillar double jib crane, design and operation features


  • It is used for lifting and moving any cargo weighing up to 3.2 tons.
  • Allows you to cover the entire working area within the radius of rotation of the boom. At the same time, the design of the crane allows the simultaneous use of two booms and parallel lifting and moving operations of the load.
  • The lifting mechanism is a manual or electric hoist (telfer) with a hook suspension for hooking the load.
  • Jib cranes are the optimal economical replacement or addition of an overhead crane in a production or storage room.

If you want to buy a pillar double jib crane, get advice on its functional differences and clarify the configuration - call the sales offices of LLC "Gruzopodem" by the phone numbers listed on the website.

The plant "Gruzopodyem" has all the permits for the manufactured equipment.

Cost request
PILLAR DOUBLE JIB CRANE CHARACTERISTICS
Crane design
Number of crane consoles
Capacity, t.
Boom outreach, m.
Lifting height (from the floor to the hook), m.
Angle of rotation, dg.
CRANE DESIGN
Type of drive
Design number of full load cycles according to ISO 4301/1
Other
Crane design
Operating temperature of the crane
Other
GOST 15150-69 bo’yicha joylashtirish toifasi
Other
CHARACTERISTICS OF THE HOIST
Type of required hoist
ADDITIONAL CRANE OPTIONS
Contact information